Kirloskar Monobloc Pumps
BCH
SPECIFICATIONS
- Head Range: Up to 57 metres
- Discharge Range: Up to 28 m3/h
- Power Ratings: 0.37 to 3.7 kW
- Voltage Range: 220 to 415 volts (three phase)
- Insulation: F class
- Protection: IP 55
- Liquid Temperature Range: 85° C
KS
SPECIFICATIONS
- Head Range: Up to 22 metres
- Discharge Range: Up to 72.5 LPS
- Power Ratings: 2.2 to 7.5 kW (3 to 10 HP)
- Voltage Range: 300 to 440 volts (three phase)
- Insulation: B / F class
- Protection: IP 44/IP 55
KDT
SPECIFICATIONS
- Head Range: Up to 98 metres
- Discharge Range: Up to 20 LPS
- Power Ratings: 3.7 to 15 kW (5 to 20 HP)
- Voltage Range: 300 to 440 volts (three phase)
- Insulation: B / F class
- Protection: IP 44 / IP 55
KDS & GMC (Three Phase)
SPECIFICATIONS
- Head Range: Up to 76 metres
- Discharge Range: Up to 49 LPS
- Power Ratings: 0.37 to 22 kW (0.5 to 30 HP)
- Voltage Range: 300 to 440 volts (three phase)
- Insulation: B class (up to 7.5 HP)/F class (above 7.5 HP)
- Protection: IP 44 / IP 55
DC
SPECIFICATIONS
- Head: Up to 25 metres
- Capacity: Up to 4.6 LPS
- Capacity: Up to 4.6 LPS
- Voltage Range: 180 to 240 volts (single phase)
KDI
SPECIFICATIONS
- Head Range: Up to 76 metres
- Discharge Range: Up to 39 LPS
- Power Ratings: 1.5 to 22 kW (2 to 30 HP)
- Voltage Range: 180 to 240 volts (single phase)
- Insulation: F class
- Protection: IP 55
KDI – EE2 Three Phase Monobloc
SPECIFICATIONS
- Head Range: up to 68 M
- Discharge Range: Up to 39 LPS
- Power Ratings: 2 HP - 10 HP
- Voltage Range: 350 to 440 Volt
- Insulation: F class
- Protection: IP 55
SRF
SPECIFICATIONS
- Head Range: Up to 94 metres
- Discharge Range: Up to 28.5 LPS
- Power Ratings: 18.3 to 22 kW (25 to 30 HP)
- Voltage Range: 300 to 440 volts (three phase)
- Insulation: F class
- Protection: IP 55
PUMBA PUZHA
SPECIFICATIONS
- Head Range: Up to 25 metres
- Discharge Range: Up to 4.6 LPS
- Power Ratings: 0.37 to 0.55 kW (0.5 to 0.75 HP)
- Voltage Range: 180 to 240 volts (single phase)
KSMB
SPECIFICATIONS
- Head Range: Up to 50 metres
- Discharge Range: Up to 17.8 LPS
- Power Ratings: 0.75 to 7.5 kW (1 to 10 HP)
- Voltage Range: 350 to 440 volts (three phase)
- Insulation: F class
- Protection: IP 44 / IP 55
- pH Value: 5 to 9
- Liquid Temperature Range: (-) 10° C to 85° C (up to 3 HP) & (-) 20° C to 100° C (5 HP and above)
KDS SINGLE PHASE
SPECIFICATIONS
- Head Range: Up to 52 metres
- Discharge Range: Up to 28 LPS
- Power Ratings: 0.37 to 3.7 kW (0.5 to 5.0 HP)
- Voltage Range: 180 to 240 volts (single phase) & 120 to 220 volts (low voltage) & 230 to 400 volts ("P" series)
- Insulation: B / F class
- Protection: IP 44 / IP 55
KAM
SPECIFICATIONS
- Head Range: Up to 19 metres
- Discharge Range: Up to 14.2 LPS
- Power Ratings: 0.37 to 1.1 kW/ (0.5 to 1.5 HP)
- Voltage Range: 120 to 220 volts (single phase low voltage) & 180 to 240 volts (single phase)
- Insulation: B class
- Protection: IP 44
Hasti
SPECIFICATIONS
- Head: Up to 25 metres
- Capacity: Up to 4.6 LPS
- Power Ratings: 0.37 to 0.55 kW (0.5 to 0.75 HP)
- Voltage Range: 160 to 240 volts (single phase)